BASIC 'AT$'
COMMAND
EXTENDED 'AT&' COMMAND
EXTENDED 'AT*' COMMAND
INFO 'ATi' COMMANDS
SET
LEASEDLINE MODE
60946 U90E 1.00 1999 12 01 16:30 ($ZYX53FF\00000000\MODEM\\ U90E 1.00 B9) OK Current settings ..... B0 E1 L4 M1 N3 Q0 V1 X5 Z4 &B1 &C1 &D2 &G0 &H3 &K4 &L0 &M0 &N0 &P0 &R1 &S0 &X0 &Y1 *C0 *D0 *E0 *F0 *G0 *I0 *M0 *P11 *Q2 S000=000 S001=000 S002=043 S003=013 S004=010 S005=008 S006=003 S007=060 S008=002 S009=006 S010=007 S011=070 S012=000 S013=000 S014=002 S015=130 S016=000 S017=022 S018=000 S019=000 S020=014 S021=178 S022=000 S023=105 S024=067 S025=000 S026=000 S027=156 S028=068 S029=000 S030=000 S031=017 S032=019 S033=000 S034=030 S035=032 S036=000 S037=000 S038=000 S039=032 S040=000 S041=000 S042=000 S043=008 S044=000 S045=100 S046=028 S047=064 S048=000 S049=006 S050=000 S051=000 S052=000 S053=000 S054=000 S055=000 S056=000 S057=016 S058=000 S059=000 S060=002 S061=000 S062=255 S063=000 S064=000 S065=000 S066=000 S067=000 S068=000 S069=000 S070=000 S071=064 S072=000 S073=009 S074=000 S075=000 S076=000 S077=000 S078=000 S079=000 S080=001 S081=000 S082=000 S083=000 S084=000 S085=000 S086=000 S087=000 S088=000 S089=000 S090=000 S091=000 S092=000 S093=000 S094=000 S095=000 S096=000 S097=000 S098=001 S099=000 S100=000 S101=000 S102=000 S103=000 S104=000 S105=008 S106=000 S107=000 S108=000 S109=000 S110=000 S111=000 S112=000 S113=000 S114=000 S115=000 S116=000 S117=000 S118=000 S119=000 S120=000 S121=000 S122=000 S123=000 S124=000 S125=000 S126=000 S127=000 |
U90E User's Manual Quick Reference Guide For Firmware Version 1.00 and higher |
| BASIC 'AT$' COMMANDSET | |
Basic command summary
Basic command summary
&$ Extended command summary I0 Product information
*$ Enhanced command summary I1 Results of ROM chksum
A Answer incoming call I2 Link report
A/ Repeat last command Ln n=0-7,Speaker volume
A> Continuously repeat command M0 Speaker off
B0 CCITT answer sequence M1 Speaker on until CD
B1 Bell answer sequence M2 Speaker always on
Dn Dial a phone number M3 Speaker off during dialing
n=0...9*#TPR,;W@!( )-
DL Redial last dialed number O0 Return on-line state
DSn Dial stored phone number O1 Like O0 with forced retrain
n=0-49 P Pulse dialing Q1
E0 Command echo disabled Q0 Return result codes
E1 Command echo enabled Q1 Quiet (no result codes)
H0 Hang up Q2 Quiet on answer mode only
H1 Off Hook
Strike any key when ready . . .
Sr.b=n Set bit .b of register r to n
( 0/Off or 1/On )
Sr.b? Inquiry bit .b of register r
Sr=n Set register r to decimal value n, n=0-255
Sr? Read contents of S Register r
T Tone dialing
V0 Numeric result codes
V1 Verbose result codes
X0 Basic result codes (0-4)
X1 Result codes (0-5, 10-21)
X2 Result codes (0-6, 10-21)
X3 Result codes (0-5, 7-21)
X4 Result codes (0-21)
X5 Error control result codes (0-21)
X6 Error control result codes (0-21)
X7 Error control result codes (0-21)
Zn n=0-3, Reset modem and load user profile n
n=4, Reset modem and load factory settings
+++ Escape sequence code
|
|
| EXTENDED 'AT&' COMMAND SET | |
Extended command summary
&B0 DTE follows linked DCE rate &K0 No error control
&B1 Fixed DTE rate &K1 MNP4 (include MNP3)
&C0 CD always on &K2 MNP4 + MNP5
&C1 Track presence of carrier &K3 V.42 + &K1
&D0 Ignore DTR &K4 V.42 + V.42bis + &K2
&D1 108.1
&D2 DTR/108.2
&D3 108.2 + load profile 0
&F Load factory settings &L0 Dial up line
&G0 No guard tone &L1 2 wire leased line
&G1 Reserved
&G2 1800 Hz guard tone &M0 Asynchronous data format
&H0 Flow control disabled &M1 Async command, sync data
&H2 Reserved &M2 Direct
&H3 Hardware CTS/RTS &M3 Synchronous
&H4 Local XON/XOFF
&H5 Reserved
Strike any key when ready . . .
&N0 Multi-Auto
&N3 V.32 9600T/9600/7200T/4800
&N4 V.32 9600/7200T/4800
&N5 V.32 4800
&N12 V.23 1200
&N14 V.22bis 2400/1200
&N15 V.22 1200
&N16 V.21 300
&N17 V.32b 14400/12000/7200
&N18 V.32b 12000/7200
&N19 V.32b 7200 &N65 V.34 21600
&N24 Bell 212A 1200 &N66 V.34 19200
&N25 Bell 103 300 &N67 V.34 16800
&N32 FAX 14400 - 2400 &N68 V.34 14400
&N60 V.34b 33600 &N69 V.34 12000
&N61 V.34b 31200 &N70 V.34 9600
&N62 V.34 28800 &N71 V.34 7200
&N63 V.34 26400 &N72 V.34 4800
&N64 V.34 24000 &N73 V.34 2400
Strike any key when ready . . .
&P0 M/B ratio = 39%/61% &Wn n=0-3, Save current settings to user
&P1 M/B ratio = 33%/67% profile n
&R0 CTS follows RTS &X0 Internal clock
&R1 Ignore RTS &X1 External clock
&S0 DSR always on &X2 Remote clock
&S1 Data set ready &Y0 Destructive, expedited
&T0 Terminate testing &Y1 Nondestructive, expedited
&T1 Analog loopback test &Y2 Nondestructive, unexpedited
&T3 Local digital loopback test &Zn=s Store the dial string s to EEPROM
&T4 Grant RDL request at location n (0-49)
&T5 Deny RDL request &Zn? Display the phone number stored
&T6 Initiate RDL in EEPROM at location n
&T7 Initiate RDL with self test
&T8 Initiate ALB with self test
&Vn n=0, View current settings
n=1-4, View user profile n-1 settings
n=5, View factory default settings
|
|
| EXTENDED 'AT*' COMMAND SET | |
Enhanced command summary
*B0 Disabled dial-backup
*Bn n=1-9, Set dial-backup phone pointer at location n-1
*C0 10 Bit character length
*C1 11 Bit character length
*C2 9 Bit character length
*C3 8 Bit character length
*Dn n=0-5, Set default dial phone pointer at location n
*E0 If error control negotiation fails, keep connection
*E1 If error control negotiation fails, terminate the call
*F0 Deny remote configuration
*F1 Accept remote configuration
*G0 Disable security function
*G1 Enable type 1 security, with password check (ZyXEL to ZyXEL only)
*G2 Enable type 1 Security, with password check and call back
(ZyXEL to ZyXEL only)
*G3 Enable type 2 security, with password check
*G4 Enable type 2 security, with password check and call back
*G5 Enable type 2 security, with password check and call back
Remote site enter the call-back number
Strike any key when ready . . .
*HS Modify supervisory password
*Hn Modify user password
*I0 AT command set *V View password table
*I1 V.25 bis command set *T Recall the last CND(Caller-ID)
*I2 Dumb mode
*M0 Leased line auto handshake on originate mode
*M1 Leased line auto handshake on answer mode
*Pn n=0-15, Leased line transmission power level
*Q0 No response to poor signal quality
*Q1 Retrain action taken if signal quality is poor
*Q2 Adaptive rate (auto fall back or fall forward)
*Q3 Disconnect
*Rab Read remote configuration *Wab Write local user profile to remote and
to local profile reset remote modem from that profile
a=0-3, Local user profile a=0-3, Local user profile
b=0-3, Remote user profile a=4, Local active profile
4, Remote current profile a=5, Local factory default
5, Remote factory default b=0-3 Remote user profile 0-3
|
|
| INFO 'ATi' COMMANDS | |
ati12 ZyXEL MODEMS PHYSICAL LAYER STATUS REPORT Modulation mode = V.90 Tx Carrier = 1920 Hz Rx Carrier = 0 Hz Tx Baud Rate = 3200 Baud Rx Baud Rate = 8000 Baud Tx Bit Rate = 28800 bps Rx Bit Rate = 50666 bps Tx Power = -17.00 dBm Rx Level = -20.60 dBm Phase Jitter = x.x degree Frequency Offset = x.x Hz SNR = 53.30 dB Round Trip Delay = 2.06 ms Near End Echo = x.x dB Eye Quality Measure = 002B Nonlinear Encoder = OFF DPCM PCM Coding = A Law Tx Shaping = Min APCM Codec Type = A Law Trellis Encoder = 16 state Digital PAD Loss = 0.00 dB Tx Filter Index = 7 TRN1d RMS value = 2000 Tx Precoder Coefficients = 0000 0000 0000 0000 0000 0000 Data Frame Intervals RBS Status = I0:N I1:N I2:N I3:N I4:N I5:N OK ati13
-0´ ² ² ² ² ²
-2´ ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-4´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-6´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-8´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-10´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-12´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-14´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-16´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-18´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-20´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-22´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-24´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-26´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ²
-28´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² AGC: -3.01 dB/0000 /0001
-30´ ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² ² IMD: 0005 /001E
dB ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Echo Pwr: -20.14/ -18.25
F 0 0 0 0 0 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 3 L1 Power: -14.69/ -13.01
R 1 3 4 6 7 0 3 5 6 9 1 2 5 7 8 0 1 3 4 6 7 L2 Power: -20.71/ -19.03
E 5 0 5 0 5 5 5 0 5 5 0 5 5 0 5 0 5 0 5 0 5 S/N: 37.42
Q 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 S/E: -0.57 dB/ 0.94
OK
ati14 ZyXEL MODEMS V.90 CAPABILITY REPORT Local Modem V.90 Capability = APCM Local Modem PSTN Connection = Analogue Remote Modem V.90 Capability = DPCM Remote Modem PSTN Connection = Digital Probing Report of APCM modem = V.90 OK ati15 ZyXEL MODEMS V.90 POWER MANAGEMENT REPORT DPCM nominal tx power for phase 2 : -12.00 dBm DPCM actual tx power for phase 2 : -18.00 dBm Maximum DPCM tx power for phase 3 : -12.00 dBm Maximum DPCM tx power measured at : Codec Digital PAD loss : 0.00 dB IMD value measured at phase 2 : 0005 DPCM tx power reduction for IMD : 0.00 dB APCM receive power at Phase 2 : -20.71 dBm APCM receive power at TRN1d : -20.60 dBm APCM receive power at Data State : -20.60 dBm ---------------------------------------------------------------- DPCM Terminal tx power : -12.29 dBm DPCM Codec tx power : -12.29 dBm OK ati17 V.90 T28800/R50666 RTG= 0 RTR= 0 FTG= 0 FTR= 0 OK ati18 CPU: 49.152MHz OK |
|
| SET LEASEDLINE MODE |
Analoge LeasedLine-Konfiguration fuer U-1496, U336 und U-90: Profil-1 ist vorkonfiguriert, dazu beim Einschalten vor der Erstkonfiguration sicherheitshalber die D/V (Data/Voice-Taste) fuer 2 Sekunden gedrueckt halten und dann loslassen. - Diesen Schleifentest mittels erneuten druck auf die D/V-Taste wieder unterbrechen. Nun die Konfiguration-String am stueck eingeben und beide Geraete ausschalten. Dann ein RJ-11 Analoges Kabel (liegt je eines bei) einfach zwischen die beiden LINE- Anschluesse verbinden und dann beide U-Series Geraete einschalten. *M0 Leased line auto handshake on originate mode *M1 Leased line auto handshake on answer mode &L1 2 wire leased line Beispiel InitStrings: ATZ1&L1*M1&W1Z1 ATZ1&L1*M0&W1Z1 |