BASIC
'AT$' COMMAND
EXTENDED 'AT&' COMMAND
EXTENDED 'AT*' COMMAND
FAX, FCLASS=6 'AT#'
ENHANCED COMMAND
VFax & VOICE COMMAND
27758 E2864 V 3.01 Current settings ..... B0 E1 L4 M1 N3 Q0 V1 X5 &B1 &C1 &D2 &G0 &H3 &J0 &K4 &L0 &M0 &N0 &P0 &R1 &S0 &X0 &Y1 *B0 *C0 *D0 *E0 *F0 *G0 *I0 *L0 *M0 *P11 *Q2 *S0 S000=000 S001=000 S002=043 S003=013 S004=010 S005=008 S006=003 S007=060 S008=002 S009=006 S010=007 S011=070 S012=000 S013=000 S014=002 S015=130 S016=000 S017=022 S018=000 S019=000 S020=014 S021=178 S022=000 S023=105 S024=067 S025=000 S026=000 S027=156 S028=068 S029=000 S030=000 S031=017 S032=019 S033=000 S034=030 S035=032 S036=000 S037=000 S038=000 S039=032 S040=000 S041=000 S042=000 S043=008 S044=000 S045=100 S046=028 S047=064 S048=000 S049=006 S050=000 S051=000 S052=000 S053=000 S054=000 S055=000 S056=000 S057=016 S058=002 S059=000 S060=002 S061=000 S062=000 S063=000 S064=000 S065=000 S066=000 S067=000 S068=000 S069=000 S070=000 S071=064 S072=000 S073=008 S074=000 S075=000 S076=000 S077=000 S078=000 S079=000 S080=000 S081=000 S082=000 S083=000 S084=000 S085=000 S086=000 S087=000 S088=000 S089=000 S090=000 S091=000 S092=000 S093=000 S094=000 S095=000 S096=000 S097=000 S098=000 S099=000 S100=000 S101=000 S102=000 S103=000 S104=000 S105=000 S106=000 S107=000 S108=000 S109=000 S110=000 S111=000 S112=000 S113=000 S114=000 S115=000 S116=000 S117=000 S118=000 S119=000 S120=000 S121=000 S122=000 S123=000 S124=000 S125=000 S126=000 S127=000 |
Elite 2864 User's Manual Quick Reference Guide For Firmware Version 3.00 and higher |
| BASIC 'AT$' COMMANDSET | |
Basic command summary
&$ or &? Extended command summary
*$ or *? Enhanced command summary
#$ or #? Hash command summary
+$ or +? FAX/Voice command summary
A Answer incoming call H0 Hang up
A/ Repeat last command H1 Off Hook
A> Continuously repeat command I0 Product information
B0 ITU-T answer sequence I1 Result of ROM checksum
B1 Bell answer sequence I2 Link report
Dn Dial a phone number Ln n=0-7, Speaker volume
n=0...9*#TPR,;W@!( )- M0 Speaker always off
DL Redial last dialed number M1 Speaker off during dialing
DSn Dial stored phone number M2 Speaker always on
n=0-49 M3 Speaker on until CD
E0 Command echo disabled
E1 Command echo enabled
Nn n=0-7, Ring volume
O0 Return on-line state
O1 Like O0 with forced retrain
P Pulse dialing
Q0 Return result codes
Q1 Quiet (no result codes)
Q2 Quiet on answer mode only
S$ or S? Summary of all S registers
Sr.b=n Set bit .b of register r to n (*)
Sr.b? Inquiry bit .b of register r (*)
Sr=d Set register r to decimal value d, d=0-255
Sr=$h Set register r to hex value h, h=00-FF
Sr=%b Set register r to binary value b, b=0-11111111 (*)
Sr=\o Set register r to octal value o, o=0-377
Sr=? Inquiry summary of S register r
Sr? Read contents of S register r
(*) = ( 0/Off or 1/On )
T Tone dialing
V0 Numeric result codes
V1 Verbose result codes
X0 Basic result codes (0-4)
X1 Result codes (0-5, 10-21)
X2 Result codes (0-6, 10-21)
X3 Result codes (0-5, 7-21)
X4 Result codes (0-21)
X5 Error control result codes (0-21)
X6 Error control result codes (0-21)
X7 Error control result codes (0-21)
Zn n=0-3, Reset modem and load user profile n
n=4, Reset modem and load factory settings
+++ Escape sequence code
|
|
| EXTENDED 'AT&' COMMAND SET | |
Extended command summary
&B0 DTE follows linked DCE rate &K0 No error control
&B1 Fixed DTE rate &K1 MNP4 (include MNP3)
&C0 CD always on &K2 MNP4 + MNP5
&C1 Track presence of carrier &K3 V.42 + &K1
&D0 Ignore DTR &K4 V.42 + V.42bis + &K2
&D1 108.1
&D2 DTR/108.2
&D3 108.2 + load profile 0
&F Load factory settings &L0 Dial up line
&G0 No guard tone &L1 2 wire leased line
&G1 Reserved &L2 4 wire leased line (e2864L only)
&G2 1800 Hz guard tone &M0 Asynchronous data format
&H0 Flow control disabled &M1 Async command, sync data
&H2 Reserved &M2 Direct
&H3 Hardware CTS/RTS &M3 Synchronous
&H4 Local XON/XOFF
&H5 Reserved
&J0 Single phone line
&J1 Multiple phone line (A/A1)
&N0 Multi-Auto &N39 ZyXEL 7200
&N3 V.32 9600T/9600/7200T/4800 &N42 CELL 14400
&N4 V.32 9600/7200T/4800 &N43 CELL 12000
&N5 V.32 4800 &N44 CELL 9600
&N12 V.23 1200 &N45 CELL 7200
&N14 V.22bis 2400/1200 &N46 CELL 4800T
&N15 V.22 1200
&N16 V.21 300 &N62 V.34 28800
&N17 V.32b 14400/12000/7200 &N63 V.34 26400
&N18 V.32b 12000/7200 &N64 V.34 24000
&N19 V.32b 7200 &N65 V.34 21600
&N24 Bell 212A 1200 &N66 V.34 19200
&N25 Bell 103 300 &N67 V.34 16800
&N32 FAX 14400 - 2400 &N68 V.34 14400
&N34 ZyXEL 19200 &N69 V.34 12000
&N35 ZyXEL 16800 &N70 V.34 9600
&N36 ZyXEL 14400 &N71 V.34 7200
&N37 ZyXEL 12000 &N72 V.34 4800
&N38 ZyXEL 9600 &N73 V.34 2400
&N78 V.90 56000 &N89 V.90 41333
&N79 V.90 54666 &N90 V.90 40000
&N80 V.90 53333 &N91 V.90 38666
&N81 V.90 52000 &N92 V.90 37333
&N82 V.90 50666 &N93 V.90 36000
&N83 V.90 49333 &N94 V.90 34666
&N84 V.90 48000 &N95 V.90 33333
&N85 V.90 46666 &N96 V.90 32000
&N86 V.90 45333 &N97 V.90 30666
&N87 V.90 44000 &N98 V.90 29333
&N88 V.90 42666 &N99 V.90 28000
&P0 M/B ratio = 39%/61% &Wn n=0-3, Save current settings to user
&P1 M/B ratio = 33%/67% profile n
&R0 CTS follows RTS &X0 Internal clock
&R1 Ignore RTS &X1 External clock
&S0 DSR always on &X2 Remote clock
&S1 Data set ready &Y0 Destructive, expedited
&T0 Terminate testing &Y1 Nondestructive, expedited
&T1 Analog loopback test &Y2 Nondestructive, unexpedited
&T3 Local digital loopback test &Zn=s Store the dial string s to EEPROM
&T4 Grant RDL request at location n (0-49)
&T5 Deny RDL request &Zn? Display the phone number stored
&T6 Initiate RDL in EEPROM at location n
&T7 Initiate RDL with self test
&T8 Initiate ALB with self test
&Vn n=0, View current settings
n=1-4, View user profile n-1 settings
n=5, View factory default settings
|
|
| EXTENDED 'AT*' COMMAND SET | |
Enhanced command summary
*B0 Disabled dial-backup
*Bn n=1-9, Set dial-backup phone pointer at location n-1
*C0 10 Bit character length
*C1 11 Bit character length
*C2 9 Bit character length
*C3 8 Bit character length
*Dn n=0-5, Set default dial phone pointer at location n
*E0 If error control negotiation fails, keep connection
*E1 If error control negotiation fails, terminate the call
*F0 Deny remote configuration
*F1 Accept remote configuration
*G0 Disable security function
*G1 Enable type 1 security, with password check (ZyXEL to ZyXEL only)
*G2 Enable type 1 Security, with password check and call back
(ZyXEL to ZyXEL only)
*G3 Enable type 2 security, with password check
*G4 Enable type 2 security, with password check and call back
*G5 Enable type 2 security, with password check and call back
Remote site enter the call-back number
*HS Modify supervisory password *S0 Secondary channel disabled
*Hn Modify user password *S1 Secondary channel enabled
*I0 AT command set *V View password table
*I1 V.25 bis command set *T Recall the last CND(Caller-ID)
*I2 Dumb mode
*L0 Panel key normal
*L1 Panel key locked
*M0 Leased line auto handshake on originate mode
*M1 Leased line auto handshake on answer mode
*Pn n=0-15, Leased line transmission power level
*Q0 No response to poor signal quality
*Q1 Retrain action taken if signal quality is poor
*Q2 Adaptive rate (auto fall back or fall forward)
*Q3 Disconnect
*Rab Read remote configuration *Wab Write local user profile to remote and
to local profile reset remote modem from that profile
a=0-3, Local user profile a=0-3, Local user profile
b=0-3, Remote user profile a=4, Local active profile
4, Remote current profile a=5, Local factory default
5, Remote factory default b=0-3 Remote user profile 0-3
|
|
| FAX, FCLASS=6 'AT#' ENHANCED COMMAND SET | |
Hash command summary
#Bn "CONNECT FAX" result code enable or disable
n=0, Disable, used in ZFAX mode, normal operation (*)
n=1, Enabled, for BBS fax receiving application, this
command also changes "CONNECT 12000/ARQ" to
"CONNECT 9600/ARQ". This will also send out
external mail string "ZyXEL" when fax is connected,
DCE will not send fax connection parameters
until <DC2> is received from DTE
n=2, Enable Polling feature of Fax. Modem will send
polling signal to remote fax machine.
n=3, Display ring cadence
n=4, Disable Polling feature of Fax.
#Cn Set minimun scan line time capability at the receiver
n=0, 20 ms at 3.85 line/mm, T(7.7)=T(3.85)
n=1, 5 ms at 3.85 line/mm, T(7.7)=T(3.85)
n=2, 10 ms at 3.85 line/mm, T(7.7)=T(3.85)
n=3, 20 ms at 3.85 line/mm, T(7.7)=1/2T(3.85)
n=4, 40 ms at 3.85 line/mm, T(7.7)=T(3.85)
n=5, 40 ms at 3.85 line/mm, T(7.7)=1/2T(3.85)
n=6, 10 ms at 3.85 line/mm, T(7.7)=1/2T(3.85)
n=7, 0 ms at 3.85 line/mm, T(7.7)=T(3.85)
#En Display line conditions (if in On-Line state)
n=0, Display mode off
n=1, Display mode on
#F Set the Modem into ZyXEL fax mode, same as AT&N32
#Ln Set maximum recording length
n=0, Set maximum recording length, A4 (297mm)
n=1, Set maximum recording length, B4 (364mm)
n=2, Set maximum recording length, unlimited.
#P<string> Set the local ID string, 25 characters max.
#Rn Set recording width
n=0, Set 1728 picture elements along a scan
line length of 215mm
n=1, Set 2048 picture elements along a scan
line length of 255mm
n=2, Set 2432 picture elements along a scan
line length of 303mm
#Tn Coding Scheme
n=0, Set to one dimensional coding scheme
n=1, Set to two dimensional coding scheme
#Vn Vertical resolution
n=0, Set to normal vertical resolution
n=1, Set to high vertical resolution
Result Code (with #B0) "CONNECT FAX/SnnnnVnTnRnLnCnP<string>"
(with #B1) "/SnnnnVnTnRnLnCnP<string>"
"DISCONNECTxP<string>"
Snnnn First four digits of Fax connection speed
Vn Vertical resolution; n =0-1
Tn Coding scheme; n =0-1
Rn Recording width; n =0-2
Ln Recording length; n =0-2
Cn Scan time; n =0-7
x Disconnect with confirmation (x=0) or without (x=1)
P<string> Remote Fax number
(*) Manufacture default (except when used to represent
AT* commands)
|
|
| Fax & VOICE COMMAND SET | |
FAX / Voice command summary
+<command>=<value> Execute a command or set a parameter.
+<command>=? Read permissible settings.
+<command>? Read current setting.
+FCLASS=n Service class selection.
n=0 Set to modem mode.
n=1 Set to Class 1 mode.
n=2 Set to Class 2 mode.
n=2.0 Set to Class 2.0 mode.
n=6 Set to ZFAX mode.
n=8 Set to Voice mode.
n=Z Set to ZyXEL fax parallel port print and/or DRAM
store mode. (See also class Z "AT+F" commands)
1. FAX, AT+V command summary
1b. Class 2.0 commands
+FAA=n
2. Voice, AT+V command summary
+FLO=n Flow control options.
n=0 No flow control.
n=1 * Set XON/XOFF software flow control.
n=2 Set CTS/RTS hardware flow control.
+VDD=<dds>,<ddi> Set the DTMF tone detection sensitivity
threshold and the required period of
continuous presence.
<dds>=0-15 *5 Set DTMF detection threshold. A lower value
means the DCE will detect DTMF tone more
sensitively. A value of "0" disables DTMF
detection
<ddi>=0-255 *8 Set the duration of DTMF tone detection,
in units of 5 ms. The modem reports
DTMF event when it detects a continuous
tone of at least this time interval
A value of "0" disables DTMF detectio
+VGR=n n=56-200 *0 Set the gain of received voice samples
Higher value results in a larger gain
(the normal value is 128). The value
of zero is for DCE automatic gain control
+VGT=n n=56-200 *128 Set the volume of playing voice
Higher value results in a louder voice
+VGN=n n=56-200 *60 Set the volume of playing tone
Higher value results in a louder tone
+VIP The DCE initializes all voice parameters to
their default settings
+VIT=n n=0-255 *70 Set the inactivity time-out timer value,
in units of 0.1 second
+VLH Request DCE hook status.
n=0 DCE is on-hook.
n=1 DCE is off-hook.
+VLS=n Voice I/O device selection
n=0 DCE is on-hook. Disconnect all I/O devices
(local phone connects to telco line).
n=1 Connects to local phone (PHONE jack.) DCE is
on-hook
n=2 DCE (modem) connects to telco line (Dial-up
line jack). DCE is off-hook
n=8 Connects to external mic. (local phone
connects to telco line). DCE is on-hook
n=16 DCE connects to internal speaker (use the internal
speaker of the modem for voice playback, local
phone connects to telco line), DCE is on-hook.
+VNH=n Automatic hang-up options
n=0 * DCE does not disable automatic hang-up
n=1 DCE disables automatic hang-up usually found
in other non-voice modes
n=2 DCE disables automatic hang-up in other non-
voice modes. DCE only performs a "logical" hang-
up (it will not really hang-up on an ATH command)
+VRA=n n=0-255 *70 Set the length of time the DCE shall wait between
ringbacks before the DCE assumes remote station
has gone off-hook, in units of 0.1 second
+VRN=n n=0-255 *10 Set the length of time the DCE shall wait while
looking for the first ringback before the DCE
assumes remote station has gone off-hook, in
units of 1 second. If the value of +VRN is
larger than S7, will take effect
+VRX Start the voice reception process
+VSD=<sds>,<sdi> Set the silence detection sensitivity
threshold and the required period of silence
<sds>=0-31 *15 Larger value means the DCE treats noisier
conditions as silence (the higher the value,
the higher the sensitivity threshold level)
Set value "0" to disable silence detection
<sdi>=0-255 *70 In units of 0.1 second, required period of
silence for detection
+VSM=n Voice compression method selection
n=2 * 19.2 Kbps 2-bit ADPCM
n=3 28.8 Kbps 3-bit ADPCM
n=30 30.72 Kbps new 3-bit ADPCM with resync capability
n=4 38.4 Kbps 4-bit ADPCM
+VSY=n n=0-255 *0 Set voice recording resync timer, in units of
50 ms. Set value "0" to disable resync generation
+VTD=<dur>,<int>
<dur>=0-255 *50 Set the DTMF tone generation duration used in
conjunction with +VTS command, in units of 10 ms
<int>=0-255 *7 set comma pause interval used in conjunction
with +VTS command, in units of 10 ms
+VTS=<string> Cause the DCE to generate DTMF and other tones
Refer to 2864 series users manual for details
+VTX Start the voice transmission process
(*) Manufacturer default (Except when used to represent AT* commands)
Snnnbx Cross reference to S-register number "nnn" bit number "x"
|
|